#5 - CAT6 UTP CCA CABLE – Download
DESCRIPTION
- CAT6 UTP LAN CABLE 23AWG CCA
- Solid Conductor
- 305m Pull box Packing
FEATURES
- CAT6 23AWG Copper Clad Aluminum Conductor
- Unshielded 23AWG Solid lan cables
- 300M Pull box Packing
APPLICATION
- 100Base-TX
- 100Base-T
- 100VG-AnyLAN
- 1000Base-T(Gigabit Ethernet)
- 1000Base-TX
- ATM
- Noisy Environments
- Installation temperature:-30℃~+70℃
Specification
Technical Data
Rated Temperature -20~75℃
Rated Voltage 30V
Conductor
Conductor | 20% Conductivity |
Material | CCA(Copper Clad Aluminum) |
AWG | 23AWG |
0.57mm |
Insulation
HDPE Dielectric Diameter | Φ1.05±0.05mm |
Material | HDPE |
Pairs Cable
- blue/blue&white
- Orange /Orange &white
- green/green&white
- Brown/Brown&white
Shielding
Foil | No |
Rip cord | Nylon |
Drain Wire | No |
Cross center
Material | Polyethylene |
Jacket
Jacket | PVC |
Jacket Diameter | 6.1mm±0.2MM |
Color | Off white |
Material | ROHS PVC |
Jacket Thickness | 0.54mm-0.56mm |
Surface | Smooth |
Packing
305m pull box | ![]() |
Performance
Electrical Characteristics at 20℃
1-250MHz Impedance | 100±15Ω |
ResistanceΩ/100m.20℃ | ≤21Ω |
Resistance Unbalance(Max) | 2.50% |
Spark test | 2000V |
Insulation resistance(Min) | 5000MΩ·km |
Operating Capacitance(Max): | 5.6nF/100m |
Allow load current(A) | 0.5A |
Transmission characteristics
Frequency | Attenuation(MHz) (dB/100m) |
1 | 1.15 |
50 | 5.71 |
100 | 8.20 |
200 | 11.61 |
400 | 16.73 |
700 | 22.15 |
1000 | 28.87 |
How To Buy Cat6 UTP CCA Cable
CCA cables are basically Copper clad Aluminium cables. They are relatively cheaper, because Aluminium is less expensive than Copper, though the tensile strength of Aluminium is low and attenuation qualities will be more in CCA cables. A Buy Cat6 UTP CCA cable in Dubai is basically Category 6 standardized unshielded twisted pair cable consisting of two unshielded wires twisted around each other. UTP cables find extensive use in telephone wiring and LANs due to their lower prices.
How to Buy
While buying a Cat6 UTP CCA cable, one should consider the features, specifications, applications of the cable and also the use for which it is needed. Category 6 patch cables, jacks, and connectors should be used with Cat 6 wiring in order to maintain good performance. The maximum length allowed for a Cat 6 cable for use in 10/100/1000BASE-T is up to 100 meters, and for use, in 10GBASE-T the length of an unshielded Cat 6 cable should not be more than 55 meters. Some of the specifications that one should consider are listed as follows.
- Rated Temperature
The approximate range is from -20 to ~75 degrees Celcius.
- Rated Voltage
This would be approximately 30 Volts.
- Conductivity
Conductivity is nearly 20%.
- Type of Shielding
Consider shielding for oil, rip cord or drain wire.
- Jacket
The jacket characteristics such as material, diameter, thickness, type of surface and so on can be considered.
- Application
This would include 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-T, 1000Base-TX, ATM, noisy environments and so on.
Conclusion
The choice of Cat6 UTP CCA cable would eventually depend on what purpose the customer needs it for and what kinds of environmental and physical conditions the cable will be expected to go through. So whether it is a burial cable or not, whether shielded or unshielded and whether solid copper or not, is for the customer to consider.
CAT6 UTP CCA CABLE